등록번호 | NFEC-2020-11-265661 | 모델명 | miniDAWN/Optilab |
---|---|---|---|---|
제작사 | Wyatt | 설치장소 | 5-1 wet lab | |
구축일자 | 2020-10-12 | 전자매뉴얼 | ||
담당자 | 이병철 |
동영상&장비사진
구성 및 교육 & 예약신청
○ Multi angle laser light scattering detector
1) Light source : 60mW GaAs linearly polarized laser
2) Laser wavelength : 658nm(nominal) Each instrument is individually characterized.
3) Laser life time : > 10,000 hours.
4) Detectors : 3 angles
5) Detector type : Custom-designed, ultra quiet hybrid photodiodes with built-in FET transimpedance amplifiers
6) Detector resolution : 24 bit
7) Mobile phase compatibility : All-solvent compatible (aqueous and organic)
8) Instrumentl options : Embedded QELS at 90 degrees
9) Scattering volume : 0.02㎕
10) Calibration : toluene(pure solvent)
11) Comet : self cell cleaning system
12) Molecular weight range : ? 200 to 10M g/mole (daltons)
13) Molecular size range : 10 to 50nm, up to 150nm with shape-specific models.
14) Computer interface : Ethernet and USB 2.0 interface
15) Processed Data Transmission rate : Software selectable from 36.6 Hz to 0.2Hz
16) Front panel display : 162.5mm 16-bit high resolution LCD display with Graphical User Interface
○ Extended range refractive index detector
1) Differential Refractive Index Range & Sensitivity:
Range (RIU) : -0.0047~+0.0047
Peak-to-peak noise (RIU) : ±7.5×10-10
2) Fliud Volumes:
Flow cell : 7.4㎕
Inlet tubing (0.010"ID) : 44㎕
Outlet tubing (0.030" ID) : 370㎕
3) Dynamic Range : 22+ bits only via digital communication
4) Response Time : 0.1~5 seconds, user selectable
5) Absolute Refractive Index Range and Sensitivity : 1.2~1.8 RIU (sensitivity of ±0.002 RIU)
6) Light Source : 658nm standard; Other wavelengths available
7) Sample Temperature Control Range : 4℃~50℃, temperature regulated
8) Temperature regulation : ±0.005℃
9) Maximum System Pressure : 30psi (2bar)
10) Maximum Cell Pressure : 100psi (7bar)
1) Light source : 60mW GaAs linearly polarized laser
2) Laser wavelength : 658nm(nominal) Each instrument is individually characterized.
3) Laser life time : > 10,000 hours.
4) Detectors : 3 angles
5) Detector type : Custom-designed, ultra quiet hybrid photodiodes with built-in FET transimpedance amplifiers
6) Detector resolution : 24 bit
7) Mobile phase compatibility : All-solvent compatible (aqueous and organic)
8) Instrumentl options : Embedded QELS at 90 degrees
9) Scattering volume : 0.02㎕
10) Calibration : toluene(pure solvent)
11) Comet : self cell cleaning system
12) Molecular weight range : ? 200 to 10M g/mole (daltons)
13) Molecular size range : 10 to 50nm, up to 150nm with shape-specific models.
14) Computer interface : Ethernet and USB 2.0 interface
15) Processed Data Transmission rate : Software selectable from 36.6 Hz to 0.2Hz
16) Front panel display : 162.5mm 16-bit high resolution LCD display with Graphical User Interface
○ Extended range refractive index detector
1) Differential Refractive Index Range & Sensitivity:
Range (RIU) : -0.0047~+0.0047
Peak-to-peak noise (RIU) : ±7.5×10-10
2) Fliud Volumes:
Flow cell : 7.4㎕
Inlet tubing (0.010"ID) : 44㎕
Outlet tubing (0.030" ID) : 370㎕
3) Dynamic Range : 22+ bits only via digital communication
4) Response Time : 0.1~5 seconds, user selectable
5) Absolute Refractive Index Range and Sensitivity : 1.2~1.8 RIU (sensitivity of ±0.002 RIU)
6) Light Source : 658nm standard; Other wavelengths available
7) Sample Temperature Control Range : 4℃~50℃, temperature regulated
8) Temperature regulation : ±0.005℃
9) Maximum System Pressure : 30psi (2bar)
10) Maximum Cell Pressure : 100psi (7bar)
○ 세포막단백질의 절대 분자량 분석
- 표준물질을 사용하지 않고 세포막단백질의 절대분자량 및 올리고머 등 분석.
- 세포막단백질 복합체의 각 분자량 및 함량 분석(membrane-detergent)
- 미확인 단백질의 특성 분석.(절대분자량, 분자량 분포, 올리고머, aggregation)
- 표준물질을 사용하지 않고 세포막단백질의 절대분자량 및 올리고머 등 분석.
- 세포막단백질 복합체의 각 분자량 및 함량 분석(membrane-detergent)
- 미확인 단백질의 특성 분석.(절대분자량, 분자량 분포, 올리고머, aggregation)
- 자료 담당자 :
- 첨단뇌연구장비센터 김보경 Tel. 053-980-5637